Echoes and sonar - CCEAHigher tier: using microphones and data logger
Sound is caused by the vibration of particles but not all vibrations can be heard as sound. Common ideas about sound come from the limited range of vibrations that human ears can detect.
A data logger can measure and record the time taken for sound to reach two microphones. Unlike the clap-echo method, these can be quite close together.
For example, two microphones are 3.4 m apart.
The data logger switches on when the sound from the bell reaches the first microphone, and off again when the sound reaches the second microphone.
The data logger recorded a time of 0.01 s for the sound to travel between the microphones.
Speed = \(\frac{\text{distance}}{\text{time}}\)
Speed = \(\frac{3.4}{0.001}\)
Speed of sound = 340 m/s.
This method works because there is no human reaction time involved starting and stopping the clock and because the microphones are more sensitive than human ears.